Lincoln Electric 300 DLX Welder User Manual


 
F-1
CONNECTION DIAGRAMS
F-1
RANGER 300 D AND 300 DLX
(RANGER 300 DLX
ONLY)
6 PIN
AMPHENOL
TO WORK
14 PIN
AMPHENOL
LN-25
N.E. PLACE IDLER SWITCH IN "AUTO" OR "HIGH" IDLE POSITION AS DESIRED.
N.C. IF REMOTE OUTPUT CONTROL IS USED, PLACE LOCAL REMOTE SWITCH IN "REMOTE" POSITION.
6-20-97
S23732-1
ELECTRODE CABLE
WIRE FEEDER
TO WORK
WORK CLIP LEAD
OPTIONAL K857
REMOTE CONTROL
N.A. WELDING CABLE MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE
AND FUTURE APPLICATIONS. SEE OPERATING MANUAL.
WARNING
or service this equipment.
Keep away from moving parts.
Only qualified personnel should install,use
RANGER 300 D & RANGER 300 DLX / LN-25 ACROSS THE ARC CONNECTION DIAGRAM
WITH OPTIONAL K857 REMOTE CONTROL
N.D. ON RANGER 300 DLX, THE WELDING TERMINALS SWITCH MUST BE IN THE "ALWAYS ON" POSITION.
N.B. USE POLARITY SWITCH TO SELECT DESIRED ELECTRODE POLARITY. POSITION THE RANGE SWITCH TO
A WIRE WELDING-CV POSITION.
Do not operate with panels open.
before servicing.
Disconnect NEGATIVE (-) BATTERY LEAD
Do not touch electrically live parts.
Keep guards in place.
ELECTRODE
TO WORK
S23732-2
RANGER 300 D & RANGER 300 DLX / LN-25 ACROSS THE ARC CONNECTION DIAGRAM
(RANGER 300 DLX
ONLY)
N.C. IF REMOTE OUTPUT CONTROL IS USED, PLACE LOCAL REMOTE SWITCH IN "REMOTE" POSITION.
N.B. USE POLARITY SWITCH TO SELECT DESIRED ELECTRODE POLARITY. POSITION RANGE SWITCH TO A
WIRE WELDING-CV POSITION.
N.A. WELDING CABLE MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE
AND FUTURE APPLICATIONS. SEE OPERATING MANUAL.
N.D. ON RANGER 300 DLX, THE WELDING TERMINALS SWITCH MUST BE IN THE "ALWAYS ON" POSITION.
6-20-97
ELECTRODE CABLE
WIRE FEEDER
OPTIONAL K444-1
REMOTE CONTROL
TO WORK
WORK CLIP LEAD
Keep guards in place.
or service this equipment.
Keep away from moving parts.
Only qualified personnel should install,use
WARNING
WITH OPTIONAL K444-1 REMOTE CONTROL
6 PIN
AMPHENOL
14 PIN
AMPHENOL
TO WORK
LN-25
Do not operate with panels open.
Disconnect NEGATIVE (-) BATTERY LEAD
before servicing.
Do not touch electrically live parts.
ELECTRODE
TO WORK
N.E. PLACE IDLER SWITCH IN "AUTO" OR "HIGH" IDLE POSITION AS DESIRED.