Lincoln Electric GX 271 Welding System User Manual


 
B-5
OPERATION
B-5
STOPPING THE ENGINE
Remove all welding and auxiliary power loads and
allow the engine to run at low idle speed for a few
minutes to cool the engine.
Stop the engine by placing the “Engine” switch in the
“STOP” position.
A fuel shut off valve is not required on the GX-271
because the fuel tank is mounted below the engine.
------------------------------------------------------------------------
GX 271 Chopper
Low Idle - No Load
2400 RPM
High Idle - No Load
3700 RPM
210 Amps @ 25 Volts
DC Weld Output
250 Amps @ 25 Volts
DC Weld Output
275 Amps @ 25 Volts
DC Weld Output
275 Amps @ 28 Volts
DC Weld Output
8,000 kVA
Auxiliary Power
K1624-1 GX-271 Honda Engine
.35 US gallons/hour
(.29 Imp. gal./hr., 1.31 liters/hour)
.76 US gallons/hour
(.63 Imp. gal./hr., 2.86 liters/hour)
1.21 US gallons/hour
(1.01 Imp. gal./hr., 4.57 liters/hour)
1.40 US gallons/hour
(1.17 Imp. gal./hr., 5.30 liters/hour)
1.53 US gallons/hour
(1.27 Imp. gal./hr., 5.79 liters/hour)
1.67 US gallons/hour
(1.39 Imp. gal./hr., 6.32 liters/hour)
1.56 US gallons/hour
(1.30 Imp. gal./hr., 5.89 liters/hour)
K1624-2 GX-271 Kohler Engine
.40 US gallons/hour
(.34 Imp. gal./hr., 1.53 liters/hour)
.87 US gallons/hour
(.73 Imp. gal./hr., 3.30 liters/hour)
1.27 US gallons/hour
(1.06 Imp. gal./hr., 4.82 liters/hour)
1.37 US gallons/hour
(1.14 Imp. gal./hr., 5.17 liters/hour)
1.44 US gallons/hour
(1.20 Imp. gal./hr., 5.45 liters/hour)
1.53 US gallons/hour
(1.28 Imp. gal./hr., 5.80 liters/hour)
1.47 US gallons/hour
(1.22 Imp. gal./hr., 5.55 liters/hour)
TABLE B.1