Lincoln Electric IM481-B Welding System User Manual


 
15
)#!(%)$#(
Model
Type
Frequency
Output Rating
Amperes
Volts NEMA EW1
IEC 974-1
Duty Cycle
Output Range (Min.)
(Max.)
Max. O.C.V.
Input Ratings
Standard Voltages
Single Voltages (Available)
Rated Current
Input kVA
Power Factor
Efficiency
Idle Current
Idle Power
Optional Features
Remote Control Adapter Cable
115V Starter Circuit
Suitable Undercarriages
Remote output Control
Other Features
Net Weight
Dimension Print
Wiring Diagram
Standards Compliance
Operating Temperature
CV 500-I
K1347
50/60 Hz
DC
500 450 400
40 38 36
39 36.5 34
50% 60% 100%
60A 12V
500A 42V
46
220/440
220/380/440
230/460
Yes
45A @ 400A 34V (380V/50 Hz)
29.6 @ 400A 34V (50 Hz)
.65 @ 400A 34V (50 Hz)
70% @ 400A 34V (50 Hz)
3.2A (380V 50 Hz)
1.0 KW (50 Hz)
Yes
Standard
Yes
Yes
Stackable Case
383 Lbs (174 kg)
M12244-7
L9269
IEC 974-1, S Rated (230/400V only)
NEMA EW1 (All others)
IP21 (All)
-40°C to +40°C