Lincoln Electric IM595-A Welding System User Manual


 
A-1
INSTALLATION
A-1
RATED OUTPUT
OUTPUT
RECOMMEND INPUT WIRE AND FUSE SIZES
REQUIRED GAS FLOW RATE REQUIRED GAS INLET PRESSURE
TECHNICAL SPECIFICATIONS - PRO-CUT 80
Duty Cycle
60% Duty Cycle
100% Duty Cycle
Current
Range
35-85 Amps
Open Circuit
Voltage
MAX
335 VDC
For all plasma cutting applications Based on U.S. National Electrical Code
Ambient Temperature 30
o
C or Less
Pilot Current
20 Amps @ 100% Duty Cycle
AMPS
80
60
VOLTS
140
130
70 PSI @ 480 SCFH
( 4.8 Bar. @ 13550 LHR)
80 to 120 PSI
( 5.4 Bar. to 8.1 Bar.)
THREE PHASE SINGLE PHASE
Standard Input Current
Voltage at Rated Output Model
208/230/460 48/44/25 50/60 Hz
200/380-415 46/27/24 50/60 Hz
460/575 25/20 50/60 Hz
Standard Input Current
Voltage at Rated Output Model
208/230/460 87/81/48 50/60Hz
INPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES
Type 75°C
Type 75°C Copper
Fuse Copper Ground
(Superlag) Wire in Wire in
Input or Conduit Conduit
Voltage Breaker AWG (IEC) AWG (IEC)
Frequency
(1)
Size Sizes Sizes
200/50/60 60 8 (8.4mm
2
) 8 (8.4mm
2
)
208/50/60 60 8 (8.4mm
2
) 8 (8.4mm
2
)
230/50/60 60 8 (8.4mm
2
) 8 (8.4mm
2
)
380-415/50/60 40 10 (6mm
2
) 10 (6mm
2
)
460/50/60 40 10 (6mm
2
) 10 (6mm
2
)
575/50/60 30 10 (6mm
2
) 10 (6mm
2
)
Type 75°C
Type 75°C Copper
Fuse Copper Ground
(Superlag) Wire in Wire in
Input or Conduit Conduit
Voltage Breaker AWG (IEC) AWG (IEC)
Frequency
(1)
Size Sizes Sizes
208/50/60 100 4 (21.1mm
2
) 4 (21.1mm
2
)
230/50/60 100 4 (21.1mm
2
) 4 (21.1mm
2
)
460/50/60 60 8 (8.4mm
2
) 8 (8.4mm
2
)
THREE PHASE SINGLE PHASE
Weight
Including Machine, Torch and
Torch Cable (Length)
(25ft/7.6m) (50ft/15.2m)
98 lbs. 113 lbs.
44.5 kg. 51.4 kg.
PHYSICAL DIMENSIONS
Depth
29.5 in.
749 mm
W
idth
13.75 in.
349 mm
Height
16.5 in.
419 mm
(1) Input voltage must be within ±10% of rated value.