Lincoln Electric IM 513-B Welder User Manual


 
– 28 –
M17323
LN-23P
LN-23P
APPLICATIONS. SEE LN-23P OPERATING
N.A. WELDING CABLES MUST BE OF PROPER
CAPACITY FOR THE CURRENT AND THE
DUTY CYCLE OF IMMEDIATE AND FUTURE
MANUAL FOR PROPER SIZES.
N.B. IF ONLY ONE LN-23P IS USED, CONNECT
TO FEEDER "A" TERMINAL STRIP IN
ADAPTER.
N.C. REMOTE VOLTAGE SENSING LEAD TO
BE EXTENDED BY CUSTOMER DIRECTLY
TO WORK USING #12 OR LARGER RUBBER
COVERED FLEX WIRE. WRAP WIRE AROUND
WORK LEAD AND TAPE.
N.D. BOLT AND TAPE CONNECTION.
602
604
521
75
76
77
602
6
04
521
75
76
77
14 PIN AMPHENOL
WORK
ELECTRODE
WIRE FEEDER "A"WIRE FEEDER "B"
ELECTRODE
21
9 CONDUCTOR ADAPTER CABLE
N.D.
N.C.
N.A.
N.B.
K350-1
LN-23P ADAPTER KIT
FEEDER "A"FEEDER "B"
Only qualified persons should install, use or
service this machine.
using the disconnect switch at the fuse box
WARNING
Turn off input power to the Welding Power Source
Before connecting the wire feeder.
ELECTRIC
SHOCK
CAN KILL
CV-
+
ENGINE WELDER WITH
115 VAC AUXILIARY
350A & SAE-300 ENGINE WELDERS WITH WIRE FEED MODULE TO LN-23P WITH ADAPTER KIT
CONNECTION DIAGRAM: COMMANDER 400 S & W, CLASSIC ll, lll, lllD, 300D, 300G, SA-250,
N.E. MOUNT ADAPTER IN A CONVENIENT
LOCATION - AS NOT TO INTERFERE
WITH THE NORMAL MACHINE OPERATION.
CAUTION: WHEN MOUNTING ADAPTER TO
WELDER, SPECIAL CARE IS TO BE
TAKEN AS NOT TO DAMAGE ANY
MACHINE COMPONENTS, SUCH AS/BUT
NOT LIMITED TO ELECTRICAL
COMPONENTS, WIRES OR FUEL TANKS.
M17323
LN-23P
LN-23P
APPLICATIONS. SEE LN-23P OPERATING
N.A. WELDING CABLES MUST BE OF PROPER
CAPACITY FOR THE CURRENT AND THE
DUTY CYCLE OF IMMEDIATE AND FUTURE
MANUAL FOR PROPER SIZES.
N.B. IF ONLY ONE LN-23P IS USED, CONNECT
TO FEEDER "A" TERMINAL STRIP IN
ADAPTER.
N.C. REMOTE VOLTAGE SENSING LEAD TO
BE EXTENDED BY CUSTOMER DIRECTLY
TO WORK USING #12 OR LARGER RUBBER
COVERED FLEX WIRE. WRAP WIRE AROUND
WORK LEAD AND TAPE.
N.D. BOLT AND TAPE CONNECTION.
602
604
521
75
76
77
602
6
04
521
75
76
77
14 PIN AMPHENOL
WORK
ELECTRODE
WIRE FEEDER "A" WIRE FEEDER "B"
ELECTRODE
21
9 CONDUCTOR ADAPTER CABLE
N.D.
N.C.
N.A.
N.B.
K350-1
LN-23P ADAPTER KIT
FEEDER "A" FEEDER "B"
Only qualified persons should install, use or
service this machine.
using the disconnect switch at the fuse box
WARNING
Turn off input power to the Welding Power Source
Before connecting the wire feeder.
ELECTRIC
SHOCK
CAN KILL
CV-
+
ENGINE WELDER WITH
115 VAC AUXILIARY
350A & SAE-300 ENGINE WELDERS WITH WIRE FEED MODULE TO LN-23P WITH ADAPTER KIT
CONNECTION DIAGRAM: COMMANDER 400 S & W, CLASSIC ll, lll, lllD, 300D, 300G, SA-250,
N.E. MOUNT ADAPTER IN A CONVENIENT
LOCATION - AS NOT TO INTERFERE
WITH THE NORMAL MACHINE OPERATION.
CAUTION: WHEN MOUNTING ADAPTER TO
WELDER, SPECIAL CARE IS TO BE
TAKEN AS NOT TO DAMAGE ANY
MACHINE COMPONENTS, SUCH AS/BUT
NOT LIMITED TO ELECTRICAL
COMPONENTS, WIRES OR FUEL TANKS.
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the
machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number.