Lincoln Electric NA-5NF Welding System User Manual


 
F-9
TROUBLESHOOTING & REPAIR
F-9
NA-5
Observe all Safety Guidelines detailed throughout this manual
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric
Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.
CAUTION
WIRE FEEDING PROBLEMS
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENTS(S)
RECOMMENDED
COURSE OF ACTION
NA-5 units above code 8300 with
“cold starting”.
The wire feeds up instead of down
when the start button is pressed.
The wire inches up and down prop-
erly.
1. Make sure the electrode wire is
fed into the welding tip.
2. Check the 1/8 amp fuse on the
voltage board. Replace if faulty.
3. Make sure electrode polarity is
correct and the same as the #67
and #21 leads at terminal strip
(TS1). See wiring diagram.
4. Make sure the welding power
source is producing welding arc
voltage.
1. Jumper the #2 and #4 leads at
the Lincoln CV power source.
Open circuit voltage should be
present at both the power source
and at the ACTUAL voltmeter
reading on the NA-5. If open cir-
cuit voltage is present at the
power source but NOT at the NA-
5 ACTUAL voltmeter reading per-
form the
#21-#67 External resis-
tance Test.
2. With the start button pressed light
7K should be lit. If it is not the
logic board may be faulty.
3. Check contactor relay 3CR.
Leads #2 and #4 are closed by
relay 3CR. Make sure the relay is
functiioning properly.
4. Check the control cable between
the power source and the NA-5
control unit. See wiring diagram.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC