Lincoln Electric NA-5NF Welding System User Manual


 
F-42
TROUBLESHOOTING & REPAIR
F-42
NA-5
TEST DESCRIPTION
This test will help the technician to determine if the T1 and/or T2 transformers are functioning
properly.
MATERIALS NEEDED
115VAC power supply
Volt-Ohmmeter (Multimeter)
5/16" Nutdriver
Slot head screwdriver
T1 and T2 TRANSFORMER TEST
Service and repair should be performed only by Lincoln Electric factory trained per-
sonnel. Unauthorized repairs performed on this equipment could result in danger to
the technician or the machine operator and will invalidate your factory warranty. For
your safety and to avoid electrical shock, please observe all safety notes and precau-
tions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform
the tests/repairs safely, contact the Lincoln Electric service department for technical
troubleshooting assistance before you proceed.
Call (216) 383-2531 or (800) 833-9353 (WELD).
_____________________________________________________________
WARNING
This procedure takes approximately 15 minutes to perform.