Lincoln Electric R3R-300 Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
F-24 F-24
IDEALARC R3R
WARNING
STATIC SCR/DIODE RECTIFIER BRIDGE TEST
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or
machine operator and will invalidate your factory warranty. For your safety and to avoid
electrical shock, please observe all safety notes and precautions detailed throughout this
manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353 (WELD).
DESCRIPTION
This test will help determine if an SCR or diode is shorted or “leaky.” See the Machine
Waveform Section of this manual for normal and abnormal output waveforms.
MATERIALS NEEDED
Analog Volt/Ohmmeter (Multimeter)
5/16” Nut driver
Idealarc R3R Wiring Diagrams (See the Electrical Diagrams section of this manual.)
This procedure takes approximately 20 minutes to perform.