Lincoln Electric R3R-500 Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
F-38 F-38
IDEALARC R3R
This is NOT the typical DC output
voltage waveform. One output SCR
is not functioning. Note the “GAP” in
the waveform. One SCR gate is dis-
connected to simulate an open or
non-functioning output SCR. Each
vertical division represents 50 volts
and each horizontal division repre-
sents 5 milliseconds in time. The
machine was loaded with a resis-
tance grid bank.
Note: Scope probes connected at
machine output terminals: (+) probe
to positive terminal, (-) probe to neg-
ative terminal. (R3R 500 machine)
SCOPE SETTINGS
Volts/Div.....................50V/Div.
Horizontal Sweep.....5 ms/Div.
Coupling ............................DC
Trigger .........................Internal
ABNORMAL OUTPUT VOLTAGE WAVEFORM
ONE OUTPUT SCR NOT FUNCTIONING
0 volts
5 ms
50 volts