Lincoln Electric R3R-500 Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
INSTALLATION
A-2 A-2
IDEALARC R3R
TECHNICAL SPECIFICATIONS - IDEALARC R3R-300
INPUT - THREE PHASE ONLY
Standard Voltage Input Current @ Rated Output
230V 56A
460V 28A
RATED OUTPUT
Duty Cycle Amps Volts at Rated Amps
100% 230 29
60% 300 32
35% 375 35
OUTPUT
Current Range Maximum Open Circuit Voltage
45 to 375 Amps 67 VDC
RECOMMENDED INPUT WIRE AND FUSE SIZES AT 60% DUTY CYCLE
Input Wire Size Ground Wire Size
Input Voltage / Fuse Input Ampere Type 75°C Type 75°C
Frequency (Super Lag) Rating on Copper Wire in Copper Ground
or Breaker Size Nameplate Conduit Wire in Conduit
Volts/Hz AWG (IEC) Sizes AWG (IEC) Sizes
230/60 80 56 8 (10 mm
2
) 8 (10 mm
2
)
460/60 40 28 10 (6 mm
2
) 10 (6 mm
2
)
PHYSICAL DIMENSIONS
Height Width Depth Weight
27.50 in. 22.25 in. 33.10 in. 350 lbs.
(700 mm) (565 mm) (840 mm) (159 kg)