Lincoln Electric R3R-500 Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
F-62 F-62
IDEALARC R3R
RETEST AFTER REPAIR (R3R 400)
Retest a machine:
• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the
machine’s electrical characteristics. OR
• If you repair or replace any electrical components.
INPUT IDLE AMPS AND WATTS
Input Volts/Phase/Hertz Maximum Idle Amps Maximum Idle KW
200/3/60 9.5 1.04
208/3/60 9.2 1.04
230/3/60 8.3 1.04
380/3/60 5.0 1.04
440/3/60 4.3 1.04
460/3/60 4.1 1.04
550/3/60 3.4 1.04
575/3/60 3.3 1.04
200/3/50 18.6 1.15
220/3/50 17.0 1.15
230/3/50 16.3 1.15
380/3/50 9.8 1.15
400/3/50 9.3 1.15
415/3/50 9.0 1.15
440/3/50 8.5 1.15
500/3/50 7.5 1.15
550/3/50 6.8 1.15
OPEN CIRCUIT VOLTAGES
Test Points Input Hertz Open Circuit Volts
Welding Output Terminals 60 63/69VDC
Welding Output Terminals 50 61/66VDC
WELDING OUTPUT LOAD TEST
Output Control Settings Amps Volts
Dial Selector at “A” 40 20VDC (Maximum)
Minimum
Dial Selector at “B” 500 43 to 47 VDC
Maximum