Lincoln Electric SVM140-A Welding System User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
INSTALLATION
A-2 A-2
PRO-CUT 55
TECHNICAL SPECIFICATIONS - PRO-CUT 55
INPUT RATINGS
Single Phase Input Input Currents Rated Output Amps
Voltage and Hertz
208/1/60 60 55
230/1/60 55 55
460/1/60 30 55
208/1/60 44 40
230/1/60 40 40
460/1/60 23 40
Three Phase Input Input Currents Rated Output Amps
Voltage and Hertz
208/3/60 31 55
230/3/60 28 55
460/3/60 17 55
208/3/60 23 40
230/3/60 21 40
460/3/60 15 40
IDLE CURRENT AND WATTS
230/1/60 0.42 Amps 98 Watts
RATED OUTPUT
Duty Cycle Rated Output Amps
50% 55
100% 40
OUTPUT
Current Range Open Circuit Voltage Pilot Current
25 - 55 Amps 335VDC Maximum 18 Amps @ 100%
Duty Cycle