Lincoln Electric SVM140-A Welding System User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
INSTALLATION
A-3 A-3
PRO-CUT 55
TECHNICAL SPECIFICATIONS (Cont’d) - PRO-CUT 55
GAS REQUIREMENTS
Required Gas Flow Rate Required Gas Inlet Pressure
70 PSI @ 360 SCHF 80 to 150 PSI
(4.8 Bar. @ 10160 LHR) (5.4 Bar. to 10.2 Bar.)
(6 CFM)
RECOMMENDED INPUT WIRE AND FUSE SIZES
For all plasma cutting applications based on U.S. National Electrical Code
Ambient Temperature 30°C or Less
AC Input V
oltage Fuse (Super Lag) Type 75°C
at Circuit Breaker Copper Wire in Conduit AWG
60 Hertz (Delay Type) (IEC) Sizes
2 Input Supply Wires 1 Ground Wire
230VAC Single Phase 70 Amps #8 (8.4mm
2
) #10 (5.3mm
2
)
460VAC Single Phase 40 Amps #8 (8.4mm
2
) #10 (.3mm
2
)
230VAC Three Phase 40 Amps #10 (5.3mm
2
) #10 (5.3mm
2
)
460VAC Three Phase 20 Amps #10 (5.3mm
2
) #10 (5.3mm
2
)
PHYSICAL DIMENSIONS
Height
Width Depth W
eight with
Torch Cable
12.6 Inches 11.0 Inches 26.0 Inches 70 lbs. (32 kg.)
320 mm 280 mm 660 mm (25 ft. cable)
85 lbs. (39 kg.)
(50 ft. cable)