12.5 Setting of Fence
12.6 Cutter Guard Setting
The cutter guard throat height is set
by turning the starknob screw (A)
clockwise or counter-clockwise.
For jointing the opening between the
fence and the guard extrusion can be
set after loosening the lock lever (B).
Before the planing beds can be
opened, the cutter guard assembly
must be swung out of the way by
180°. Loosen lever (C), swing
assembly over and retighten lever.
A
B
C
C
The 90° position of the fence extru-
sion against the planing beds can be
set by adjusting setting screw (C).
Notice: Always set fence so it rests
flush on the planing tables (see arrow).
12.7 Setting Depth of Cut/Scale Reading
Prior to any adjustment loosen
ratchet lever (A) approx. 1/2 turn.
Turning the knurled setting handle (B)
raises or lowers the infeed table.
The set depth of cut is indicated by the
venier scale. After required depth of
cut is set retighten the ratched lever
(A).
1 matching 1 = 1 mm depth of cut
2 matching 2 = 2 mm depth of cut
etc.
A
B
➞