Miller Electric 1000 Welder User Manual


 
OM-2221 Page 11
SECTION 3 INSTALLATION
3-1. Specifications
Voltage
Amperage
Max Open
-
RMS Amps Input at Rated Load Output, 3-Phase at
NEMA Load
Voltages and Class I Rating
AC or DC
Rated Output
V
o
lt
age
Range in
CV Mode
A
mperage
Range in
CC Mode
M
ax.
O
pen-
Circuit
Voltage
380/400/415 V
(50/60 Hz)
460 V
(60 Hz)
500 V
(50/60 Hz)
575 V
(60 Hz)
KVA KW
1000 A at 44 V,
100% Duty Cycle;
2544 V
2501250 A
71 V
143 124 114 100 98 53
100% Duty Cycle;
1250 A at 44 V,
60% Duty Cycle
2
544
V
2
5
0
12
5
0 A
7
1 V
143
(3*)
124
(3*)
114
(3*)
100
(3*)
98
(2.37*)
53
(0.95*)
*While idling
3-2. Duty Cycle and Overheating
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
If unit overheats, high temperature
shutdown light turns On, thermo-
stat(s) opens, output stops, and
cooling fan runs. Wait fifteen min-
utes for unit to cool. Reduce amper-
age or duty cycle before welding.
NOTICE Exceeding duty cycle
can damage unit and void warranty.
Overheating
0
15
A/V
OR
Reduce Duty Cycle
Minutes
duty1 4/95 181 560
Continuous Welding
100% Duty Cycle At 1000 Amperes