SECTION 7 SETTING DUAL SCHEDULE PARAMETERS
7-1. Selecting Dual Schedule Pair
Dual Schedule is used with two
consecutive weld programs 1 & 2,
3 & 4, 5 & 6, or 7 & 8. Any program
type (MIG, Adaptive Pulse, or
Pulse) can be combined in dual
schedule.
1 Side Panel Display
Use side panel to turn feature on.
See Menu Guide for detailed
programming steps.
2 Front Panel Display
Press front panel parameter select
button to select program number.
3 Front Panel Display Control
4 Dual Schedule Switch (See
Section 7-2)
. Switch type is set in System
Setup.
5 Welding Gun Trigger
Selecting dual schedule program A
or B is done by using Display Con-
trol, dual schedule switch, or gun
trigger (depending on system
setup).
When program B is active, turn
Display Control one click clockwise
to select another pair of dual sched-
ule programs.
. Programs can be rearranged in
desired order using the data
card. See Section 8.
Process
Sequence
>Dua l Schd
Ca rd
>Pr g 1&2
On
2
18. 0V
200 IPM
>Pr g 1
Dua l A
>Pr g 2
Dua l B
>Pr g 3
Dua l A
4
3
5
Or
Display
Control
Display
Control
1