Miller Electric 280 NT Welding System User Manual


 
. A complete Parts List is available at www.MillerWelds.com
OM-4430 Page 28
6-6. Stick Start Procedure Scratch Start Technique
With Stick selected, start arc as
follows:
1 Electrode
2 Workpiece
3 Arc
Drag electrode across workpiece like
striking a match; lift electrode slightly
after touching work. If arc goes out
electrode was lifted to high. If
electrode sticks to workpiece, use a
quick twist to free it.
1
2
3
6-7. TIG Lift-Arc Start Procedure
Select Lift-Arct/Scratch Start TIG at
Process switch to achieve great arc
starts with either procedure. Perform
Lift-Arc starting method as follows:
Lift-Arc t TIG
1 TIG Electrode
2 Workpiece
Turn gas on. Touch tungsten
electrode to workpiece at weld start
point. Hold electrode to workpiece
for 1 second, and slowly lift electrode.
Arc is started when electrode is lifted.
Normal open-circuit voltage is not
present before tungsten electrode
touches workpiece; only a low sensing
voltage is present between electrode
and workpiece. The solid-state output
contactor does not energize until after
electrode is touching workpiece. This
allows electrode to touch workpiece
without overheating, sticking, or
getting contaminated.
Application:
Lift-Arc is used for the DCEN GTAW
process when HF Start method is not
permitted.
1
1
Second
“Touch”
2
Lift-Arc Start Method
Do NOT Strike Like A Match!