OM-230 009 Page 22
6-4. Jog/Purge Switch
804 668-B
3
2
1 Jog/Purge Switch
2 Gun Trigger Receptacle
3 Adjust Control
Pressing the Jog/Purge switch
allows the operator to jog wire
without energizing the weld pow-
er or gas valve circuit.
• Jog speed can be adjusted by
the Adjust control when the
unit is jogging wire. The unit
displays jog speed when the
unit is being jogged.
• Pressing the Jog/Purge button
also allows the operator to
purge gas lines before welding
and to preset gas pressure at
the regulator.
1
6-5. Front Panel Controls
Program
Start
Crater
Pre/Postflow
Trigger Hold
Adjust
V/Trim Time (sec)
Wire Speed Amps
Sequence Setup
Dual Schedule
See
Section
6-7
See
Section
6-8
See
Section
6-11
See
Section
6-10
See
Section
6-9
See
Section
6-6