Miller Electric PipePro Dual Welder User Manual


 
OM-230 009 Page 28
6-13. Remote-14 Receptacle Information
804 667-B
1 Remote Switch
2 Remote-14 Receptacle
If the remote switch is set to MIG,
the feeder operates normally. A re-
mote control may be left attached
while the remote switch is in the
MIG mode, as the remote has no af-
fect on the operation of the wire
feeder.
If the remote switch is set to Stick/
TIG, the feeder controls and meter
displays are disabled, allowing con-
trol from a standard remote control.
When a remote control is con-
nected to the remote-14 receptacle,
the PipePro 450 RFC will automati-
cally adjust output control in a pri-
mary/secondary configuration, but
the power source must be set for
remote operation (see the PipePro
450 RFC Owner’s Manual for infor-
mation).
In this configuration, the Amp Ad-
just control on the PipePro 450 RFC
power source becomes the prima-
ry, and sets the maximum amper-
age output of the unit. The remote
control becomes the secondary,
and provides an amperage range
adjustment of 0 to 100% of what is
set on the Amp Adjust control on the
power source.
. When in Stick/Tig mode, re-
mote program select is still
functional from the feeder.
! Do not connect a Stick elec-
trode holder and a MIG gun
to the same output terminal
at the same time, as both
will be live when the contac-
tor is on. An external polar-
ity reversing isolation con-
trol should be used to iso-
late the outputs.