SECTION 6 SETUP AND OPERATION
6-1. Safety Equipment
Wear the following during
operation:
1 Dry, Insulating Gloves
2 Safety Glasses With Side
Shields
DO NOT wear rings or watches
during operation.
sb3.1* 1/94
12
6-2. System Description
The ProHeat 35 Induction Heating Power Source is designed to function either as an air-cooled system or a liquid-cooled system. Depending on the
system type (either air-cooled or liquid-cooled), the power source is automatically configured to operate and provide an output appropriate for the type
of connected heating device.
A special identifier, embedded within the extension cable connector, provides the means for the power source to configure itself by recognizing the type
of extension cable(s) attached to its output connectors.
Designed to provide a single level of output (up to 35 kW), the ProHeat 35 power source has two panel mounted connectors that are connected in
parallel to the power source output. This design allows the system to operate with either a single output extension cable or two output extension cables.
If a single output extension cable is used, a protective plug (provided with the system) MUST be placed on the unused output connector or the system
will not operate. If two output extension cables are used, they both MUST be of the same type (either both air-cooled or both liquid-cooled) or the system
will not operate (in this case, the protective plug is not used). When two extension cables and heating devices are utilized on the system, the extension
cable lengths and heating devices MUST be identical (see Section 4-7).
The ProHeat 35 is intelligent to the point that it will automatically adjust output power levels if internal system operating parameters or internal tempera-
tures reach or exceed specific set limits (see Section 9).
6-3. Power Source/System Setup
To view the System Setup screen, simultaneously press the Parameters
Hz
V
A
kW
and Program buttons and the following screen will appear
on the display:
Degree Units: >_F SYSTEM SETUP
Tolerance...: ±25 Backlight: Yes
Input Type..: K TC Control Mode: Manual
Power Output: 35 KW System Lock: No
System Setup Screen
To change a setting:
S Press the Cursor button to move the cursor to the parameter to be changed
S Press Increase or Decrease button to select desired set-up feature.