Miller Electric ProHeat 35 Welding System User Manual


 
OM-222 166 Page 34
6-5-2. Manual Control
Mode.....: Manual TC5: 77
Power....: 0.0 KW TC6: 77
Countdown: −−:−−:−−
Status...: Stopped
Run Status Screen
During active operation, Power shows the actual power delivered from the power source, Countdown shows the time remaining in the heating cycle,
and Status indicates if the system is running or stopped. TC5 and TC6 display the temperature of thermocouples 5 and 6. This screen is for
monitoring purposes only.
. No changes can be made to the run status screen, and the Cursor, Increase and Decrease buttons are not functional.
6-6. Parameters
During active operation, the Parameters screen allows the operator to monitor the power source output operating parameters. These parameters in-
clude output power, output amperage, output voltage, and output frequency. In addition, temperatures of thermocouples TC5 and TC6 are also
displayed. The Parameters screen is for monitoring purposes only and has no selectable or changeable parameters.
Power....: 0.0 KW TC5: 77
Current..: 0 A TC6: 77
Voltage..: 0 V
Frequency: 4.5 KHz
Parameters Screen
6-7. Cooler
The Cooler button is used to turn the cooler On or Off on systems using liquid-cooled output cables. Systems using liquid-cooled output
cables will not deliver output unless the cooler is On. If the cooler is not started prior to initiating a heating cycle, the system will automatically start the
cooler when the Run button is pressed. Pressing the Stop button does not shut off the cooler. The cooler must be shut off separately
by pressing the Cooler button.
When power source output is energized, the cooler cannot be turned off. If the Cooler button is pressed while output is energized, the follow-
ing screen will appear on the display:
Cooler cannot be turned off
while output is on
Cooler Message Screen