Miller Electric ProHeat 35 Welding System User Manual


 
OM-222 166 Page 45
S OPEN no cable or plug in place
ClntFR This is the coolant flow rate (in GPM) from the cooler on a liquid-cooled system.
ClrSts This is the status of the cooler. Possible labels:
S Off
S Flowing
The second diagnostic screen is available by again pressing and holding the Run Status button and pressing the Parameters
Hz
V
A
kW
button.
VLnAB: 460V Therm1: 75 DIAG2
VLnBC: 460V Therm2: 75 Therm5: OPEN
VLnCA: 460V Therm3: 75 ClrTmp: 77
VBus: 650V Therm4: OPEN RmtFlw: Off
System Diagnostic Screen
VLnA-B This is the phase to phase line voltage between phases A and B.
VLnB-C This is the phase to phase line voltage between phases B and C.
VLnC-A This is the phase to phase line voltage between phases C and A.
VBus This is the DC bus voltage.
Therm1 This is the temperature of the current source primary heatsink.
Therm2 This is the temperature of the bridge heatsink.
Therm3 This the the temperature of the current source secondary heatsink.
Therm4 Open (not used).
Therm5 Open (not used).
ClrTmp This is the temperature of the coolant on a liquid-cooled system.
S OPEN no cooler is detected.
RmtFlw This is the status of the relay contacts for remote coolant flow on a liquid-cooled system.
S OFF
S ON
. RmtFlw feature is unsupported on the current platform.