Miller Electric XMS 4000 Welder User Manual


 
OM-224 043 Page 21
4-12. Selecting Synergic MIG Welding
Set Synergic MIG welding process using
P3 push button.
In Synergic MIG mode, the operator may
need to adjust welding data (wire type, wire
diameter, and gas type) and only one weld
parameter. Generally, wire feed speed is
adjusted and the synergic process auto-
matically sets appropriate weld voltage.
Synergic welding also sets many secon-
dary welding parameters automatically for
improved weld quality.
During Setting :
D1 value is default voltage setting (range is
defined by wire type, wire diameter and gas
type selection).
D2 value is the default current setting
(range is defined by wire type, wire diame-
ter and gas type selection).
During Synergic MIG Welding:
D1 value is Measured Welding Voltage in
Volts.
D2 value is Measured Welding Amperage
in Amperes.
See Wire Feeder manual for all remaining
Synergic MIG settings.
Select wire type using P4 push button.
Select wire diameter using P5 push button.
Select trigger mode using P7 push button.
See Wire Feeder manual for all remaining
Synergic MIG settings.
Setting Cooler Status (see Section 4-11)
E1 D1 D2 E2
P3 P6P4 P5