52
Circuit Breakers
Three thermal circuit breakers are located inside the top of the Console.
Fig. 34 — Circuit Breaker location
Under normal circumstances circuit breakers do not require service; they are
automatically re-set when an overload condition is corrected. If a breaker is
cycling on/off, locate the cause of the electrical overload and repair as required.
Maximum Cut Depth Adjustment
This saw comes factory-adjusted for maximum usable cut depth. However,
should you desire to change this setting:
1. Park the blade-less saw on a flat and level surface.
2. Fully lower the saw onto the Stop Bolts (see Fig. 35).
3. Measure the distance from the Blade Collars to the surface.
4. Adjust the Stop Bolts in or out until the Blade Collars have 1/8” to 3/16”
ground clearance.
5. Ensure that both bolts are adjusted to the same settings so the load is evenly
distributed.
Remove Panel to
access circuit