RATINGS
MAXIMUM CONTINUOUS OUTPUT POWER: Varies with model number of the inverter:
EXPORT VERSIONS
FX2012ET 2000 VA
FX2024ET 2000 VA
FX2348ET 2300 VA
VFX2612E 2600 VA
VFX3024E 3000 VA
VFX3048E 3000 VA
MAXIMUM AC OUTPUT FAULT CURRENT:
The FX will go into fault if a sustained current draw of 25 amps RMS when operating as an inverter. When passing an AC
source through the FX via the AC transfer switch, the maximum AC output fault current will be determined by the AC source.
NOMINAL DC VOLTAGE OUTPUT:
The last two digits in the model number designate the nominal DC voltage.
Example: FX2324ET24V DC Voltage.
MAXIMUM OVERCURRENT PROTECTION AMPACITY:
EXPORT
AMPACITY DC BREAKER DC FUSE
FX2012ET 250 amps OBDC-250 SMF-250
FX2024ET 175 amps OBDC-175 SMF-175
FX2348ET 100 amps OBDC-100 SMF-100
VFX2612E 250 amps OBDC-250 SMF-250
VFX3024E 175 amps OBDC-175 SMF-175
VFX3048E 175 amps OBDC-175 SMF-175
OBDC are panel mount circuit breakers. SMF are DC terminal mounted fuses and should always be used in conjuncture with
a disconnect. FX’s used in home installations should use properly sized DC breakers. A DC breaker includes both
overcurrent protection and disconnect capability. SMF fuses are used primarily for marine installations where a DC
disconnect is not required.