-19-
W1737/W1738 Owner's Manual (Mfg. 10/09+)
Digital display and key pad.
Table height handwheel.
When pushed, the emergency stop plate shown in
stops the electricity to the motors and also applies
anair-discbraketostopthesanderimmediately.
Pushthebottomoftheemergencystopplate.
Holdtheemergencystopplateuntilthesanderhas
come to a complete stop.
Emergency stop plate.
You can push the or arrow keys to lift or
lower the table, or you can use the automated function
ofautoheightadjustmentforyournextsandingpass.
Allfunctionsarecontrolledthroughthekeypadandare
presented on the digital display. See .
InputLED
Run
LED
Up and
Down
Keys
When you change the sandpaper or you notice an
inconsistency with the actual sanding thickness in
relationshiptoyourdigitalsetting,youmustre-calibrate
the table.
Sand a workpiece multiple times at the same
thickness until no sanding occurs when the
workpiece goes through the sander.
Using a caliper capable of measuring 0.001",
measure and record the workpiece thickness.
Type the recorded thickness of the workpiece on
the key pad, and the digital display will show the
thickness. For 1
1
⁄2"thickness,type1.500;
or for 1
3
⁄8" thickness, type 1.375.
Nowpressandholdthe key for 3 seconds:
The table is now calibrated.
Holding the set key for 10 seconds toggles
the digital readout between metric and standard
measurements.
Emergency
StopPlate