Sterling Plumbing 822.00247.00 Paint Sprayer User Manual


 
1 –Pump 9-Station Controller Chapter 3: Installation 18 of 38
Viewing System Status
The station and pump status screen (Shown below) can be viewed by pressing the F2 key on
the controller keypad.
Figure 3: Status Screen
This screen will show whether stations 1-9 and the pump (shown in the bottom right of the
screen- “P1”) are Ready or Offline. For a list of additional station and pump status names
and their description which may be displayed on this screen, see below.
Figure 4: Station Status Names & Descriptions
Name Description
OFFLINE Station is disabled or not installed.
READY Normal idle condition.
DEMAND Station is in demand, waiting to convey.
CONVEY Convey to station is in progress.
UNLOAD Convey is complete, station is now unloading.
NOCONV Station has a no convey alarm.
PURGE Station convey is complete – lines are being purged.
HIVAC High vacuum alarm.
Figure 5: Pump Status Names & Descriptions
Name Description
OFFLINE Pump is disabled.
READY Pump is idle and off.
IDLE Pump is idle and running.
CONVEY Pump is conveying or purging.
HIVAC High vacuum alarm.
PMP FLT Pump Verify alarm.
GEN FLT User input alarm.
FLTR CAN Filter can limit switch alarm.
Note: Pressing F1 while this screen is active will turn On or Off the conveying
system.
Press F6 to return to the Main Menu.