Tripp Lite APS INT 512 Welding System User Manual


 
12
Limited Warranty
Tripp Lite warrants its products to be free from defects in materials and workmanship for a period of one year (domestic) or 120 days
(export) from the date of initial purchase. Tripp Lite’s obligation under this warranty is limited to repairing or replacing (at its sole option)
any such defective products. To obtain service under this warranty you must obtain a Returned Material Authorization (RMA) number
from Tripp Lite or an authorized Tripp Lite service center. Products must be returned to Tripp Lite or an authorized Tripp Lite service
center with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of
date and place of purchase. This warranty does not apply to equipment which has been damaged by accident, negligence or
misapplication or has been altered or modified in any way. This warranty applies only to the original purchaser who must have properly
registered the product within 10 days of purchase.
EXCEPT AS PROVIDED HEREIN, TRIPP LITE MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some states do not permit limitation or exclusion of implied
warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser.
EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL
OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY
OF SUCH DAMAGE. Specifically, Tripp Lite is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use
of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise.
Maintenance & Service
Maintenance
The APS series requires no maintenance but should be kept dry at all times. Periodically check all
cable connections both at the unit and at the battery. Clean and tighten as necessary.
Service
If returning your APS to Tripp Lite, please carefully pack the APS using the ORIGINAL PACKING
MATERIAL that came with the unit. Enclose a letter describing the symptoms of the problem. If the
UPS is within the warranty period, enclose a copy of your sales receipt.
Specifications
INVERTER APS INT 512
Continuous power 20° C: 500 Watts
Surge power (5 seconds): 1200 Watts
Efficiency (Full Load): 90%
DC Input Current @ 12V DC -Full Load: 52 Amps
-No Load: 1 Amp
Nominal Input Volts: 12 VDC
DC Input Voltage Range: 10 to 15.5V DC
Nominal Output Volts: 230 VAC +/- 5%
Nominal Output Frequency: 50/60Hz +/- .3%
Waveform: Modified Sine
BATTERY CHARGER
Charging Capacity DC: 18 Amps
Acceptance Volts VDC: Selectable ’14.4/14.2 Wet/Gel
Float Volts VDC: Selectable ’13.3/13.6 Wet/Gel
Input Voltage AC: 230 VAC
Input Current AC: 5 Amps
LINE VAC OPERATION
Minimum Input AC Volts: Selectable 144, 162, 181 or 200 VAC
Maximum Input AC Volts: Selectable 257 or 276 VAC
Maximum Input Current: 11 Amps
Input Frequency: 50/60Hz +/-10%
Maximum Output AC: 5 Amps
Automatic Transfer Time: 6 milliseconds nominal
Dimensions (H x W x D): 17.4 x 17.4 x 25.4 cm
Weight: 8.2 kg.