30
B_00304
R max < 1 M Ω
OPERATING MANUAL
VERSION 12/2012 ORDER NUMBER DOC 2330426
6.4 GROUNDING EXCEPT FOR NONCONDUCTIVE PLASTIC UNITS
Grounding schema (example)
Paint container
Electrostatically conductive ooring
Conveyor
Work piece
Spraying stand
Heavy paint mist if grounding is insu cient!
Danger of poisoning.
Insu cient paint application quality.
Ground all device components.
Ground the work pieces to be coated.
WARNING
Discharge of electrostatically charged components in atmospheres
containing solvents!
Explosion hazard from electrostatic sparks.
Clean the pump only with a damp cloth.
WARNING