Wagner SprayTech B_04001 Paint Sprayer User Manual


 
31
B_04001
OPERATING MANUAL
VERSION 12/2012 ORDER NUMBER DOC 2330426
The ground connection is at the pumps of metal and conductive acetal imperative.
Note: Pump of nonconductive plastic have no ground connection.
Procedure:
1. Remove the crimp connection delivered with the pump.
2. Crimp the grounding cable on the terminal and screw it back onto the pump’s foot.
3. Ground the material/paint container to a local ground connection.
4. Ground the other parts of the system to a local ground connection.