Wagner SprayTech B_04001 Paint Sprayer User Manual


 
34
B_04014
OPERATING MANUAL
VERSION 12/2012 ORDER NUMBER DOC 2330426
Close the return valve, if installed.
Let the solvent  ow through the pump for 2 or 3 minutes.
6.5.3 UNIT PRESSURE TIGHTNESS TEST
Close the material delivery valve, once the pump is primed.
Gradually increase the pressure until reaching the maximum allowed value for the pump
and the devices connected to it. Ensure that the  ttings do not leak.
Opened
Opened
Closed
Delivery
Discharge
(Return line)
Air