Wagner SprayTech GM 5000EAC Paint Sprayer User Manual


 
19
GM 5000EAC.
1
2
3
4
R1
R3
R2
B_03182
2
4
3
R1
R3
R2
E
B_03262
16
OPERATING MANUAL
EDITION 03/2012 PART NUMBER DOC 2319150
4.4.2 FUNCTIONS OF THE SPRAY GUN
Distance Description
1 AirCoat air opens.
2 AirCoat air opened and electrostatic (HV)
activated.
-> Display (2) for „spray current“ on the spray
gun ●❍❍❍❍ to ●●●●● activated.
3 AirCoat air opened and electrostatic (HV)
activated and material valve opened.
4 Max way of trigger.
An increase in the tension needed to pull the trigger back
will be felt at the position where the material valve opens.
For spraying without high-voltage, the high-voltage can
be switched off using the operating button (4). Press the
operating button (4) briefl y: High-voltage is switched off.
The standby display (3) illuminates.
In the event of a malfunction the spray gun switches to
„standby“ operating mode and the display (3) illuminates.
The width of the spray jet can be adjusted using the air
adjustment (16) (only for fl at-jet method).
The trigger can be used to activate, one after the other, the
various functions of the spray gun.
When the spray gun is connected to the control unit
and the control unit is switched on, the pre-defi ned
recipe (R1, R2 or R3) is shown on the gun display (2) as
follows.
Recipe 1 -> ●❍❍❍❍ R1
Recipe 2 -> ●●●❍❍ R2
Recipe 3 -> ●●●●● R3
Recipe change R1 -> R2 -> R3 -> R1
Press the operating button (4) and hold the button
pressed of at least 2 seconds, then it is advanced by
1 recipe.
Display (2) -> ●●❍❍❍ = recipe values changed temporarily:
The stored recipe values of the previously selected recipe
number are re-loaded from memory by pressing the operating
button (4) for 2 seconds.