Wagner SprayTech GM 5000EAC Paint Sprayer User Manual


 
29
GM 5000EAC.
B_03690
84
84
84
B_03691
84
OPERATING MANUAL
EDITION 03/2012 PART NUMBER DOC 2319150
Check the level of the release agent in the Wagner pneumatic pump and if necessary
ll the release agent up.
Provide material container, containers for detergent and an empty container for
return.
Connect the system with a safe gun to the air and power supply.
A basic fl ushing of system must be carried out for initial start up. Make sure, that no
nozzle is inserted into the gun.
SIHI_0139_ENG
WARNING
Sparks form when the plug is removed!
Explosion hazard
When using the spray gun in explosion hazard areas:
 The cable connection may neither be separated nor put together
in this area. Cover sleeve plus warning sign have to be secured
over the screw on the connector.
Attention: gun cable to control unit
Cover sleeve with warning sign have to be secured over the screw (84) on the connector.
Attention: guns with electrical extension cable
Cover sleeves with warning signs have to be secured over the screws (84) on the connectors.
Extension cable to the
control unit
GM 5000E gun cable
GM 5000E gun cable