10-12 CRA NKSHAF T/TRANSMISSION
Crankcase
Install the breather tube [A] on the crankcase fitting.
Align the w hite line on the tube with the mark [B] on the
crankcase.
Face the open end of the clamp [C] towards the left side
[D] as shown.
Apply grease to the steel ball [A] and spring [B].
Install:
Steel Ball
Spring
Washer [C]
Shift Shaft Positioning Bolt [D]
Tighten:
To rque - Shift Shaft Positioning Bolt: 25 N·m (2.5 k g f·m, 18
ft·lb)
Check:
Crankshaft and driven shaft turn freely.
If any of the shafts do not turn freely, split the crankcase
to locate the problem.