Agilent Technologies 6812B Welding System User Manual


 
Language Dictionary - 3
55
Output Subsystem
This subsystem controls the main outputs, the signal outputs, the power-on state, and the output
protection function of the ac source.
Subsystem Syntax
OUTPut
[:STATe] <bool> Enable/disable output voltage, current, power, etc.
:COUPling <coupling> Enables ac or dc output coupling (AC | DC)
:DFI
[:STATE] <bool> Enable/disable DFI output
:SOURce <source> Selects an event source (QUES | OPER | ESB | RQS | OFF)
:IMPedance
[:STATE] <bool> Enable/disable output impedance programming
:REAL <n> Sets resistive part of output impedance
:REACtive <n> Sets inductive part of output impedance
:PON
:STATe <state> Set power-on state (*RST | *RCL0)
:PROTection
:CLEar Reset latched protection
:DELay <n> Delay after programming/before protection
:RI
:MODE <mode> Set remote inhibit input (LATC | LIVE | OFF)
:TTLTrg
[:STATE] <bool> Enable/disable trigger out drive
:SOURce <source> Selects a TTLTrg source (BOT | EOT | LIST)
OUTPut
This command enables or disables the output. The state of a disabled output is an output voltage
amplitude set to 0 volts, with output relays opened.
The query form returns the output state.
Command Syntax
OUTPut[:STATe] <bool>
Parameters
0 | 1 | OFF | ON
*RST Value
OFF
Examples
OUTP 1 OUTP:STAT ON
Query Syntax
OUTPut[:STATe]?
Returned Parameters
0 | 1
Related Commands
*RCL *SAV