Power and Data Cabling Requirements
Power
The Bad Boy™ Spot Luminaire requires standard AC power distribution from 200-240 VAC, 50/60
Hz, 15A maximum. The upper enclosure provides a Neutrik® connector for power input. Use the
provided AC Line Cord Cable Assembly (25.9812.0902.5) to connect power.
Figure 2-1: Power Input Connector
Refer to "AC Line Current / Power vs. Voltage" on page 83 for details on power consumption at
various voltages.
Data
DMX512 Cables
The Bad Boy Luminaire is equipped with two, 5-pin XLR connectors for DMX IN and DMX THRU
(out) applications. DMX IN requires a 5-pin, female XLR connector and DMX THRU requires a 5-
pin, male XLR connector. When purchasing or constructing data cables, it is important that not only
the correct cable type be used, but also quality cable to ensure a reliable DMX512 system. Your
cabling should meet the following USITT DMX specification requirements:
Suitable for use with EIA485 (RS485) operation at 250k baud.
Characteristic impedance 85-150 ohms, nominally 120 ohms.
Low capacitance.
Two twisted pairs.
Foil and braid shielded.
24 AWG minimum gauge for runs up to 1000 feet (300m).
22 AWG minimum gauge for runs up to 1640 feet (500m).
Note: Microphone type cables and other general purpose, two-core audio or signal cables are not
suitable for use with DMX512.