Comm LED Operation
The Comm LED - located on the upper enclosure connector
panel - indicates system control status. This can be used
determine if the luminaire is receiving a control signal. LED
indications are as follows:
Green - The Comm LED will light green if either DMX
or Ethernet control is present. Note that if both valid
DMX and Ethernet control are being received, DMX
control will take precedence.
Red - The Comm LED will light red if no DMX or
Ethernet is present.
Bypassing Calibration
If the menu screen is touched (in the center) and held during startup, the
luminaire will present a menu that provides the option to bypass
calibration. This feature allows the luminaire to skip the calibration
sequence so that it can be powered up in the case for configuration
purposes.
To bypass calibration:
Step 1. Connect power to luminaire.
Step 2. At startup, touch center of menu screen and hold until Bypass
Calibration menu appears.
Step 3. Press Yes to bypass calibration. (The menu will
automatically dismiss if no selection is made within 5
seconds.)
Step 4. Proceed with programming of starting address or other options.
CONFIG
addr
043
univ A
1400w
COMM
IN
DMX
THRU
LAMP
hrs
125
temp 34C
INFO
01:34
TEST
COMM
DMX
STATUS
OK
Comm LED
Figure 2-12: Comm LED