Delta 33-891 Saw User Manual


 
4
1. TO REDUCE THE RISK OF KICKBACK AND OTHER INJURIES, KEEP GUARDS IN PLACE and in working order.
2. REMOVE ADJUSTING KEYS AND WRENCHES. Form habit of checking to see that keys and adjusting wrenches are
removed from spindle before turning tool on. Tools, scrap pieces, and other debris can be thrown at high speed, causing
injury.
3. KEEP WORK AREA CLEAN. Cluttered areas and benches invite accidents.
4. DO NOT USE THE MACHINE IN A DANGEROUS ENVIRONMENT. The use of power tools in damp or wet locations
or in rain can cause shock or electrocution. Keep your work area well-lit to avoid tripping or placing arms, hands, and
fingers in danger.
If your saw is of double-insulated construction, read the following instructions.
Double-insulated tools are constructed throughout with two separate layers of electrical insulation or one double thickness
of insulation between you and the tool's electrical system. Tools built with this insulation system are not intended to be
grounded. As a result, your tool is equipped with a two-prong plug which permits you to use extension cords without concern
for maintaining a ground connection.
NOTE: Double insulation does not take the place of normal safety precautions when operating this tool. The insulation system
is for added protection against injury resulting from a possible electrical insulation failure within the tool.
POLARIZED PLUGS
To reduce the risk of electric shock, this equipment has a polarized plug (one blade is wider than the other).
This plug will fit in a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse the
plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug
in any way.
IMPORTANT SAFETY INSTRUCTIONS
The 120/240 volt, dual-voltage motor supplied with your
machine was shipped prepared for 120 volt operation. It
can be converted for 240 volt operation.
Use the following instructions to convert your saw to 240
volts.
1. Remove the screw (C) Fig. D and remove the
nameplate cover (B).
2. Carefully slide the switch (C) Fig. D in the motor
junction box to read 240 volts. Replace the nameplate
cover and screw that were removed in STEP 1.
3. You must also replace the 120 volt plug with a UL/CSA
listed plug suitable for 240 volts and the rated current
of the saw.
Either use a qualified electrician to do the conversion,
or take the machine to an Authorized Delta Service
Center. The machine must conform to the National Electric
Code and all local codes and ordinances.
Use the 240 volt plug ONLY in an outlet that has the same
configuration as the plug illustrated in Fig. C. DO NOT use
an adapter with the 240 volt plug.
Disconnect the machine from the power source!
Fig. C
Fig. D
A
B
C
240 VOLT SINGLE PHASE OPERATION
DOUBLE INSULATION