GROUNDING INSTRUCTIONS
THIS MACHINE MUST BE GROUNDED WHILE IN USE TO PROTECT THE OPERATOR FROM
ELECTRIC SHOCK.
Permanently connected machines:
If the machine is intended to be permanently connected, all wiring must be done by a qualified electrician and conform to the
National Electric Code and all local codes and ordinances.
* THREE PHASE OPERATION: Three phase machines are not supplied with a power cord and must be permanently
connected to a building’s electrical system. Extension cords can’t be used with a three phase machine.
* LVC MAGNETIC MOTOR CONTROL: If you purchased a machine that has a Low Voltage Magnetic Motor Control
System, refer to its instruction manual for installation guidance.
FOREWORD
FUNCTIONAL DESCRIPTION
NOTICE: The photo on the manual cover illustrates the current production model. All other illustrations contained in
the manual are representative only and may not depict the actual labeling or accessories included. These are are
intended to illustrate technique only.
The Delta Unisaw is a 10" right tilting arbor saw. The Delta Unisaw features set the standards in the table saw industry.
CARTON CONTENTS
1
1. Unisaw
2. Switch (shown with a LVC switch)
2
POWER CONNECTIONS
MOTOR SPECIFICATIONS
A separate electrical circuit should be used for your machines. This circuit should not be less than #12 wire and should be
protected with a 20 Amp time lag fuse. Before connecting the machine to the power line, make sure the switch is in the “OFF”
position and be sure that the electric current is of the same characteristics as indicated on the machine. All line connections
should make good contact. Running on low voltage will damage the machine.
DO NOT EXPOSE THE MACHINE TO RAIN OR OPERATE THE MACHINE IN DAMP LOCATIONS.
Your machine is wired for 230 Volt, 60 HZ alternating current. Before connecting the machine to the power source,
make sure the switch is in the “OFF” position.