Excell Precision E7540 Air Compressor User Manual


 
16-ENGA18791
MAINTENANCE
Customer Responsibilities
Daily
or after
each
use
Before
each
use
Every
8
hours
Every
40
hours
Every
100
hours
Yearly
Every
160
hours
1
1- more frequent in dusty or humid conditions
Check Safety Valve
Drain Tank
Oil Leaks
Check Oil
Change Oil
Air Filter
Unusual Noise and/or
Vibration
Drive Belt-Condition
Motor Pulley/Flywheel alignment
Air compressor pump intake
and exhaust valves
Inspect air lines and fittings
for leaks
Head Bolts - Check the torques of the head bolts after the first five hours of operation.
Risk of Unsafe Operation. Unit cycles automatically when
power is on. When servicing, you may be exposed to volt-
age sources, compressed air, or moving parts. Before servicing unit unplug
or disconnect electrical supply to the air compressor, bleed tank of pres-
sure, and allow the air compressor to cool.
To ensure efficient operation and longer life of the air compressor, a routine
maintenance schedule should be prepared and followed. The above routine
maintenance schedule is geared to an air compressor in a normal working
environment operating on a daily basis. If necessary, the schedule should be
modified to suit the conditions under which your air compressor is used. The
modifications will depend upon the hours of operation and the working environ-
ment. Compressors in an extremely dirty and/or hostile environment will require
a greater frequency of all maintenance checks.
NOTE: See Operation section for the location of controls.
To Check Safety Valve
Risk of Bursting. If the safety valve does not work properly,
over-pressurization may occur, causing air tank rupture or
an explosion.
1. Before starting compressor, pull the ring on the safety valve to make sure
that the safety valve operates freely. If the valve is stuck or does not operate
smoothly, it must be replaced with the same type of valve.