Fluke 39 Work Light User Manual


 
Specifications
63
Safety
Designed for 600V measurements on industrial power distribution circuits.
Overload Protection:
Voltage or Current Probe Input: 600V, maximum
Surge Protection: 6 kV per IEC 1010-1
Maximum Voltage Isolation to Earth: 600V from any terminal
Protection Levels:
IEC 1010-1, Pollution Degree 2, Installation
Category III, Material Group II, 600V
Protection Class:
Protection Class II as described in IEC 1010-1, Annex H (Double or
Reinforced Insulation
).
Waveform Memory (Model 41B)
Eight nonvolatile memories store 2048 sampled points of waveform data for
both Voltage and Current inputs for later recall or sending to a computer.
EIA-232-E (RS-232) INTERFACE (Model 41B)
Optically-Isolated, 1.2, 9.6, or 19.2k baud rate.
Printer graphical output in either Epson or HP format. Text data is sent is
ASCII format (SEND). Waveform, Data, and Picture formats may be remotely
accessed. Remote Trigger function.