Graco AA2000 Paint Sprayer User Manual


 
Service
27
SERVICE NOTES:
A
Gasket (33) must be replaced if fluid connector (67 or l-see page 14) is removed
or replaced.
A
Fluid leakage into air chambers may result if new gasket is not installed.
Lubricate threads
An/ .
A
Apply anaerobic pipe sealant to threads
A
Apply high strength sealant to threads
A
Thread nut to bottom thread of needle
A U-cup lips face inward
A
Torque to 23-27 ft-lb (31-37 Nom)
A
Torque to 20-24 ft-lb (27-32 Nom)
A
Torque to 15- 19 ft-lb (20-26 Nom)
Q
Torque to 4-6 in-lb (5-8 Nom)
Fig. 7
307-947 13