Graco GM100 Glue Gun User Manual


 
Installation
FlushFlush
Flush
NOTE:NOTE:
NOTE:
Do NOT cycle the module until the
temperature set point has been achieved. Cycling
the module below the temperature set point may
cause premature seal leakage.
1. Disconnect or turn off the device which triggers
the solenoid valve.
2. Ensure the nozzle (Z) is removed.
3. Heat the system to working temperature.
4. Place waste container under the applicator to
catch the adhesive.
5. Press the manual override switch (M) to manually
trigger the solenoid valve.
6. Dispense hot melt (adhesive) until it is clean.
Figure 8 Flush
InstallInstall
Install
NozzleNozzle
Nozzle
Use 1/2 in. wrench to install nozzle. See
Kits and Accessories, page 37.
Figure 9 Install Nozzle
SelectSelect
Select
RTDRTD
RTD
NOTE:NOTE:
NOTE:
For InvisiPac systems only.
Identify RTD type used in applicator on the system
Advanced Display Module (ADM). The RTD type is
listed on the manifold cover plate.
NOTICENOTICE
NOTICE
An incorrect RTD setting will cause the system
to be incapable of maintaining the temperature
setting. The applicator may overheat and trip the
thermal cutoff, if the applicator uses a PT 100 (385)
and NI 120 is selected on the ADM Setup screen.
The applicator may under-heat if the applicator
uses a NI 120 and PT 100 (385) is selected on the
ADM Setup screen.
If PT 100 (385) is listed, select PT 100 (385) in the
ADM Setup screens.
If NI 120 is listed, select NI 120 in the ADM Setup
screens.
334627D
11