Graco H25 Paint Sprayer User Manual


 
Setup
24 312062W
Maintain and inspect the generator, air
compressor, and other equipment per the
manufacturer recommendations to avoid
an unexpected shutdown. Unexpected
equipment shutdown will cause voltage
fluctuations that can damage electrical
equipment.
Use a wall power supply with enough cur-
rent to meet system requirements. Failure
to do so will cause voltage fluctuations that
can damage electrical equipment.
3. Electrical requirements
See Table 1.
* Full load amps with all devices operating at
maximum capabilities. Fuse requirements at
various flow rates and mix chamber sizes may
be less.
** Total system watts, based on maximum
hose length for each unit:
Parts 255400 through 255408, 310 ft (94.6
m) maximum heated hose length, including
whip hose.
Parts 253400 through 253408, 410 ft (125
m) maximum heated hose length, including
whip hose.
Installing this equipment requires access to
parts which may cause electric shock or
other serious injury if work is not performed
properly. Have a qualified electrician connect
power and ground to main power switch ter-
minals, see page 25. Be sure your installa-
tion complies with all National, State and
Local safety and fire codes.
Table 1
: Electrical Requirements
(kW/Full Load Amps)
Part Model
Voltage
(phase)
Full
Load
Peak
Amps*
System
Watts**
253400 H-40 230V (1) 100 23,100
253401 H-40 230V (3) 71 26,600
253402 H-40 400V (3) 41 26,600
253403 H-XP3 230V (1) 100 23,100
253404 H-XP3 230V (3) 95 31,700
253405 H-XP3 400V (3) 52 31,700
253407 H-40 230V (3) 95 31,700
253408 H-40 400V (3) 52 31,700
255400 H-25 230V (1) 69 15,960
255401 H-25 230V (3) 46 15,960
255402 H-25 400V (3) 35 15,960
255403 HXP2 230V (1) 100 23,260
255404 HXP2 230V (3) 59 23,260
255405 HXP2 400V (3) 35 23,260
255406 H-25 230V (1) 100 23,260
255407 H-25 230V (3) 59 23,260
255408 H-25 400V (3) 35 23,260
253725 H-50 230V (1) 100 23,100
253726 H-50 230V (3) 71 26,600
253727 H-50 400V (3) 41 26,600
256505 H-50 230V (3) 95 31,700
256506 H-50 400V (3) 52 31,700
Table 1
: Electrical Requirements
(kW/Full Load Amps)
Part Model
Voltage
(phase)
Full
Load
Peak
Amps*
System
Watts**