Graco H25 Paint Sprayer User Manual


 
Shutdown
38 312062W
Shutdown
1. Shut off , , and heat
zones.
2. Park pumps.
a. Press .
b. Trigger gun until pump A stops in the
retracted position and the pressure of
both pumps bleeds down.
3. Turn main power OFF .
4. Relieve pressure, page 39.
5. Turn off the air compressor and air dryer, if
included.
6. Open air compressor bleed valve to relieve
pressure and remove water from tank.
7. Turn off the main breaker on the generator.
8. Allow generator dwell time, per manufac-
turer recommendations, prior to shutdown.
9. Close both fluid supply valves (FV).
10.Shut down feed pumps as required.
NOTICE
Proper system setup, startup, and shutdown
procedures are critical to electrical equip-
ment reliability. The following procedures
ensure steady voltage. Failure to follow
these procedures will cause voltage fluctua-
tions that can damage electrical equipment
and void the warranty.
A
B
ti9883a
FV