Graco H25 Paint Sprayer User Manual


 
Setup
312062W 25
4. Connect electrical cord
Table 2: Power Cord Requirements
a. 230V, 1 phase: Using 5/32 or 4 mm hex
allen wrench, connect two power leads
to L1 and L2. Connect green to ground
(GND).
b. 230V, 3 phase: Using 5/32 or 4 mm hex
allen wrench, connect three power
leads to L1, L2, and L3. Connect green
to ground (GND).
Power cord is not supplied. See Table 2.
Part Model
Cord Specification
AWG (mm
2
)
253400 H-40 4 (21.2), 2 wire + ground
253401 H-40 4 (21.2), 3 wire + ground
253402 H-40 8 (8.4), 4 wire + ground
253403 H-XP3 4 (21.2), 2 wire + ground
253404 H-XP3 4 (21.2), 3 wire + ground
253405 H-XP3 6 (13.3), 4 wire + ground
253407 H-40 4 (21.2), 3 wire + ground
253408 H-40 6 (13.3), 4 wire + ground
255400 H-25 4 (21.2), 2 wire + ground
255401 H-25 8 (8.4), 3 wire + ground
255402 H-25 8 (8.4), 4 wire + ground
255403 H-XP2 4 (21.2), 2 wire + ground
255404 H-XP2 6 (13.3), 3 wire + ground
255405 H-XP2 8 (8.4), 4 wire + ground
255406 H-25 4 (21.2), 2 wire + ground
255407 H-25 6 (13.3), 3 wire + ground
255408 H-25 8 (8.4), 4 wire + ground
253725 H-50 4 (21.2), 2 wire + ground
253726 H-50 4 (21.2), 3 wire + ground
253727 H-50 8 (8.4), 4 wire + ground
256505 H-50 4 (21.2), 3 wire + ground
256506 H-50 6 (13.3), 4 wire + ground
L1
L2
GND
ti2515b
L1
L2
GND
ti3248b
L3