Graco H25 Paint Sprayer User Manual


 
Models
6 312062W
H-XP2 SERIES
H-XP3 SERIES
* Full load amps with all devices operating at maximum capabilities. Fuse requirements at vari-
ous flow rates and mix chamber sizes may be less.
Total system watts, based on maximum hose length for each unit:
Parts 255400 through 255408, 310 ft (94.6 m) maximum heated hose length, including whip
hose.
Parts 253400 through 253408, 253725 through 253727, 256505, and 256506, 410 ft (125 m)
maximum heated hose length, including whip hose.
Maximum flow rate given for 60 Hz operation. For 50 Hz operation, maximum flow rate is 5/6 of
60 Hz maximum flow.
CE approval does not apply.
Approvals:
Part, Series
Full Load
Peak Amps*
Per Phase
Voltage
(phase)
System
Watts†
Primary
Heater
Watts
Max Flow
Rate
gpm (lpm)
Approximate
Output per
Cycle (A+B)
gal. (liter)
Hydraulic
Pressure
Ratio
Maximum Fluid
Working
Pressure
psi (MPa, bar)
255403, F 100 230V (1) 23,260 15,300 1.5 (5.7) 0.042 (0.16) 2.79:1 3500 (24.1, 241)
255404, F 59 230V (3) 23,260 15,300 1.5 (5.7) 0.042 (0.16) 2.79:1 3500 (24.1, 241)
255405, F 35 400V (3) 23,260 15,300 1.5 (5.7) 0.042 (0.16) 2.79:1 3500 (24.1, 241)
Part, Series
Full Load
Peak Amps*
Per Phase
Voltage
(phase)
System
Watts†
Primary
Heater
Watts
Max Flow
Rate
gpm (lpm)
Approximate
Output per
Cycle (A+B)
gal. (liter)
Hydraulic
Pressure
Ratio
Maximum Fluid
Working
Pressure
psi (MPa, bar)
253403, E 100 230V (1) 23,100 12,000 2.8 (10.6) 0.042 (0.16) 2.79:1 3500 (24.1, 241)
253404, E 95 230V (3) 31,700 20,400 2.8 (10.6) 0.042 (0.16) 2.79:1 3500 (24.1, 241)
253405, E 52 400V (3) 31,700 20,400 2.8 (10.6) 0.042 (0.16) 2.79:1 3500 (24.1, 241)

#ONFORMSTO!.3)5,
3TD#ERTIFIEDTO
#!.#3!3TD
#.O