Graco Inc. 222625 Paint Sprayer User Manual


 
14 308018
Operation
05151A
Fig. 4
06615
20
1
26
45
43
31
DD
Selecting a Fluid Nozzle and Air Cap
WARNING
PRESSURIZED EQUIPMENT HAZARD
To reduce the risk of an injury, follow the Pressure
Relief Procedure on page 13 before removing or
installing a fluid nozzle and/or air cap.
The gun is supplied with a 0.059 in. (1.5 mm) fluid
nozzle, P/N 185158, and air cap, P/N 193033. If your
application requires a different nozzle and air cap
combination, use instruction manual 307803 or consult
your authorized Graco distributor to select the ap-
propriate fluid nozzle and air cap. Install the air cap
and fluid nozzle into the gun barrel as instructed in Air
Cap/Nozzle/Resistor Stud Replacement, page 24.
Operating the Spray Gun
WARNING
PRESSURIZED EQUIPMENT HAZARD
To reduce the risk of an injury, follow the Pressure
Relief Procedure on page 13 whenever you stop
spraying and whenever you are instructed to
relieve pressure.
WARNING
COMPONENT RUPTURE HAZARD
To reduce the risk of component rupture,
which can cause serious injury, do not
exceed the maximum working pressure
of the lowest rated system component. This equip-
ment has a 100 psi (7 bar, 0.7 MPa) maximum
working air and fluid pressure.
Follow the steps on page 15 to establish the correct
fluid flow and air flow. Do not turn the ES ON-OFF
lever to ON yet.