Grizzly G0755 Drill User Manual


 
-32-
Model G0755 (Mfg. Since 1/13)
Ball Oilers
Oil Type ......Model T23963 or ISO 32 Equivalent
Oil Amount ......................................... 1–2 Pumps
Lubrication Frequency ...........8 Hrs. of Operation
Proper lubrication of ball oilers (shown in
Figures 4546) is done with a pump-type oil
can that has a plastic or rubberized cone tip (see
Page 27 for offerings from Grizzly). We do not
recommend using metal needle or lance tips, as
they can push the ball too far into the oiler, break
the spring seat, and lodge the ball in the oil galley.
Push the tip of the oil can nozzle against the ball
oiler to create a hydraulic seal, then pump the oil
can once or twice. If you see sludge and contami-
nants coming out of the lubrication area, continue
pumping the oil can until the oil runs clear. When
finished, wipe away the excess oil.
Table/Column Ways & Quill
Oil Type ......Model T23962 or ISO 68 Equivalent
Oil Amount ............................................Thin Coat
Lubrication Frequency ...........8 Hrs. of Operation
Refer to Figures 4548 to identify each compo-
nent to lubricate.
Figure 48. Outside surface of the quill.
Quill
Use the component controls to access the entire
length of the surfaces, then clean them with min-
eral spirits and shop rags.
When dry, apply a thin coat of oil to the surfaces.
Move each component through the entire path of
travel several times to distribute the lubricant.
Figure 45. Y-axis ball oiler and ways.
Y-Axis
Ball Oiler
Y-Axis Table Ways
Figure 46. X-axis ball oiler and ways.
X-Axis
Ball Oiler
X-Axis
Table Ways
Figure 47. Column ways.
Column
Ways