Grizzly G0755 Drill User Manual


 
Model G0755 (Mfg. Since 1/13)
-33-
Quill Rack & Pinion
Oil Type ................ NLGI#2 Grease or Equivalent
Oil Amount ............................................Thin Coat
Lubrication Frequency ....... 90 Days of Operation
Move the quill up and down to gain full access to
the rack and pinion (see Figure 51), then clean
the teeth with mineral spirits, shop rags, and a
brush.
Table Leadscrews
Oil Type ......Model T23962 or ISO 68 Equivalent
Oil Amount ............................................Thin Coat
Lubrication Frequency .........40 Hrs. of Operation
Move the table as necessary to access the entire
length of the X- and Y-axis leadscrews (see
Figures 4950), then use mineral spirits, shop
rags, and a brush to clean them.
Note: Use a 4mm hex wrench to remove the way
cover from the column and access the Y-axis
leadscrew.
Use a brush to apply a thin coat of grease to the
teeth, then raise/lower the quill several times to
distribute the grease.
Note: Re-apply oil to the smooth outside surface
of the quill that was removed during the cleaning
process.
Use a clean brush to apply a thin coat of oil to the
leadscrew threads, then move the table through
the X- and Y-axis paths to distribute the oil.
Replace the way cover before connecting the
machine to power.
Figure 49. X-axis leadscrew.
X-Axis Leadscrew
Figure 50. Y-axis leadscrew.
Y-Axis Leadscrew
Figure 51. Quill rack and pinion.
Pinion
Rack